INSTALLATION INSTRUCTIONS
Clarus 5050 Series Recirculating Float & Splitter Valves
© Copyright 2014. All rights reserved.
INSTALLATION INSTRUCTIONS AND PREINSTALLATION CHECKLIST
1. Inspect materials upon delivery. Occasionally, products
are damaged during shipment. If materials are damaged,
contact your dealer prior to installation.
2. Read the relevant literature and installation instructions
carefully to become familiar with the product and proper
installation procedures.
3. The use of a septic tank efuent lter is strongly
recommended in order to protect downstream
components from accumulating solids.
All installations must comply with
applicable electrical and plumbing codes, including,
but not limited to, National Electrical Code, local,
regional, and/or state codes, etc.
The splitter valve must be level across the outlets.
Be sure the disposal pipe does not settle after
the splitter valve is installed.
Figure 1 5050-0002
Recirculating Float Valve
Figure 2 5050-0003 Splitter Valve
Part Number Description Minimum Riser Diameter
5050-0001
Recirculating Float Valve and
Splitter Valve Combo
36"
5050-0002 Recirculating Float Valve 24"
5050-0003 Splitter Valve 24"
5080-0011 4" Pipe Seal N/A